PROCEDURE 1
Remove shelves.
Remove crispers.
Remove shelf cover.
Remove partition plate.
Hold the cover and turn
in counter-clockwise
direction to loosen cover.
Then, remove cover.
Use 6mm cross-head screwdriver to loosen the screw in counter clockwise direction.
Hold the edge of air duct to pull it out.
Disconnect the terminal for fridge temp. sensor.
CHECK AND TEST 1
Connect damper terminal to terminals inside fridge.
Unscrew cover of mainboard with a cross- head screwdriver.
Strip off sleeves of wires in PCB area, and supply signal to damper from terminal in PCB area.
An oscilloscope should display a square wave signal.
See if damper door opens gradually.
DIAGNOSIS 1
PROCEDURE 2
Unscrew with 6mm cross-head screwdriver.
Disconnect the terminal
Lift the plastic cover off of the damper.
Take damper out of air duct in foam.
CHECK AND TEST 2
Use a standard signal producer to supply square wave to damper from terminal in fridge area.
DIAGNOSIS 2
CHECK AND TEST 3
In duct area, check if terminal is pushed into final position.
Check if terminal is filled
with foam or not.
IF YES, please use
tweezers to clean and
remove the foam.
Check to ensure that wires are in proper order.
IF WIRE ORDER IS WRONG, PLEASE FOLLOW PROCEDURE 3 TO CORRECT THEM.
Check to make sure wire
order in the foam is right
and/or see if it’s been cut H
off.
Use multimeter to test
connections.
a. Put detector into one
end of wires in PCB
area;
b. Put another detector
into end of wires
behind air duct.
DIAGNOSIS 3
DIAGNOSIS 4
PROCEDURE 3
Cut the wire
Peel off the sleeves.
Check to ensure proper wire order and reconnect them.
Tin soldering.
Cover connecting point with electrical tape.
CHECK AND TEST 4
Connect damper terminal to terminals inside fridge.
Strip off sleeves of wires in PCB area, and supply signal to damper from terminal in PCB area.
An oscilloscope should display a square wave signal.
See if damper door opens gradually.
DIAGNOSIS 5
PROCEDURE 4
Put damper into air duct in foam.
Put the plastic cover on top of damper.
Connect the terminal.
Screw with 6mm cross-head screwdriver.
PROCEDURE 5
Re-connect the terminals.
Hold air duct by edges to put it back in place.
Use a 6 mm cross-head screwdriver to tighten the screw clockwise.
Hold the cover and turn it clockwise to tighten the lid, then move it backwards.
Insert partition plate.
Insert shelf cover.
Insert crispers.
Insert shelves.
TIPS DURING INSTALLATION PROCEDURES FOR FRIDGE AIR DUCT.
Connect the terminals.
Push terminals into place, then move wires to prevent crushing of wires with edge of air duct.
When reinstalling the air duct, first insert positive shaft into the negative hole.
Then, fasten the clasp on top using the same method.
DIAGNOSIS 6
Power on the appliance, then open the doors on the same side to the same degree, wait 5 seconds, and put your hand in front of fridge air duct outlet to verify.