CHECK AND TEST 1
Open left fridge door to see if gasket plate turns up and down automatically.
DIAGNOSIS 1
CHECK AND TEST 2
To assess whether rework was successful, place a torch on shelf with light pointed towards the gasket.
Close the door to see if any light is visible from interior.
DIAGNOSIS 2
CHECK AND TEST 3
Blow hot air on gasket with a hair dryer to soften gasket, so it can be easily attached to cabinet.
Place a torch on shelf
with light pointed
towards the gasket.
Close the door again to see if any light is visible from interior.
If light still leaks out from interior, place the front edge of a steel ruler parallel to the gasket plate. Then, measure the gap between the ruler and the plate.
DIAGNOSIS 3
PROCEDURE 1
Remove the screw cover in the middle.
Loosen 2 screws
of terminal cover in
anticlockwise direction.
Disconnect the terminal.
Use 2 hands to move gasket plate up.
Lift gasket plate up until negative end is released from positive end of fastener.
PROCEDURE 2
Connect the terminals then place wires carefully so they will not be crushed by cover.
Check to make sure gasket plate can turn properly up and flat when doors are opened and closed.
Blow hot air on gasket with a hair dryer to soften gasket, so it can be easily attached to cabinet.
To assess whether rework was successful, place a torch on shelf and point light towards gasket.
Close door to see if there is any light leaking out.
DIAGNOSIS 2