CHECK AND TEST 1

Step 1

Open left fridge door to see if gasket plate turns up and down automatically.

DIAGNOSIS 1


CHECK AND TEST 2

Step 1

To assess whether rework was successful, place a torch on shelf with light pointed towards the gasket.

Step 2

Close the door to see if any light is visible from interior.

DIAGNOSIS 2


CHECK AND TEST 3

Step 1

Blow hot air on gasket with a hair dryer to soften gasket, so it can be easily attached to cabinet.

Step 2

Place a torch on shelf with light pointed towards the gasket.

Step 3

Close the door again to see if any light is visible from interior.

Step 4

If light still leaks out from interior, place the front edge of a steel ruler parallel to the gasket plate. Then, measure the gap between the ruler and the plate.

DIAGNOSIS 3


PROCEDURE 1

Step 1

Remove the screw cover in the middle.

Step 2

Loosen 2 screws
of terminal cover in anticlockwise direction.

Step 3

Disconnect the terminal.

Step 4

Use 2 hands to move gasket plate up.

Step 5

Lift gasket plate up until negative end is released from positive end of fastener.

PROCEDURE 2

Tip 1

Connect the terminals then place wires carefully so they will not be crushed by cover.

Tip 2

Check to make sure gasket plate can turn properly up and flat when doors are opened and closed.

Step 1

Blow hot air on gasket with a hair dryer to soften gasket, so it can be easily attached to cabinet.

Step 2

To assess whether rework was successful, place a torch on shelf and point light towards gasket.

Step 3

Close door to see if there is any light leaking out.

DIAGNOSIS 2