CHECK AND TEST 1
Unscrew cover of mainboard with a crosshead screwdriver.
Disconnect terminals.
Check for proper wire positions.
Record test result.
DIAGNOSIS 1
CHECK AND TEST 2
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Measure the resistance of heater from terminal under hinge cover.
DIAGNOSIS 2
CHECK AND TEST 3
Check to see if terminal is full of foam.
IF YES, USE TWEEZERS TO REMOVE FOAM.
Connect 2 ends of terminals in PCB area, and test resistance from terminal under hinge cover.
DIAGNOSIS 3
PROCEDURE 1
Remove the screw cover in the middle.
Loosen 2 screws of terminal cover in anticlockwise direction.
Disconnect the terminal.
CHECK AND TEST 4
Measure the resistance of heater from terminal in gasket plate.
DIAGNOSIS 4
CHECK AND TEST 5
Connect 2 ends of terminal in cavity of wires on door, and test resistance from terminal under hinge cover.
DIAGNOSIS 5
PROCEDURE 2
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Unscrew 3 bolts and remove the top hinge.
Remove fridge door.
Don’t forget to add washer onto hinge pin.
When installing door on hinge, please make sure door-stopper and hinge are properly aligned.
Make sure gasket is attached properly.
Make sure gaps between doors are even.
Check to make sure gasket plate turns over properly when door is opened and closed.
PROCEDURE 4
Disconnect the terminal for earthing wire.
Use 2 hands to move gasket plate up.
Lift gasket plate up until negative end detaches from positive end.
PROCEDURE 3
Connect the terminals then place wires carefully so they will not be crushed by cover.
DIAGNOSIS 6