PROCEDURE 1
Push a 6mm sucker onto display and turn the knob to strengthen suction force.
Attach strap to knob to facilitate pulling out display board.
PROCEDURE 2
Lever off the cover on door cap.
Remove the screws (in total 2).
Pull out the plastic.
PROCEDURE 3
Unscrew hinge cover.
Remove the cover
PROCEDURE 4
CHECK AND TEST 1
Check whether the
display terminal is
properly plugged in.
a) Metal door;
b) Glass door.
Check whether terminal in hinge cover is properly plugged in.
Check to see if terminal in Mainboard cover is properly plugged in.
DIAGNOSIS 1
CHECK AND TEST 2
Check to make sure the
wire order for display is correct.
a) Metal door;
b) Glass door.
If wire order in customer’s product is not identical to pictures, the wire order is incorrect.
Check to make sure the wire order in hinge cover is correct.
Check to make sure the
wire order on mainboard
is correct.
If wire order in customer’s product is not identical to pictures, the wire order is incorrect.
DIAGNOSIS 2
PROCEDURE 5
Cut off the wire.
Peel off the sleeves.
Make sure wires are in proper order and connect them.
Tin soldering.
Cover connecting point with electrical tape.
CHECK AND TEST 3
Check to see if terminals
for display board are
dirtied by foam.
a) Metal door;
b) Glass door.
Check to see if terminals under hinge cover are dirtied by foam.
Check to see if terminal in Mainboard cover is dirtied by foam.
DIAGNOSIS 3
Use tweezers to remove visible foam.
CHECK AND TEST 4
Use multimeter to test connection of wires in foam.
Check the connection between terminals in mainboard cover and hinge cover.
Check the connection between terminals in display cover and hinge cover.
DIAGNOSIS 4
PROCEDURE 6
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Unscrew 3 bolts and remove the top hinge.
Remove fridge door.
Reverse procedures above to reinstall hinges and door, but please pay attention to points below.
Don't forget to put washer onto hinge pin.
When installing door on hinge, please make sure door-stopper and hinge are properly aligned.
Make sure gasket is attached properly.
Make sure gaps between doors are even.
Check to make sure gasket plate turns over properly when door is opened and closed.
DIAGNOSIS 5
PROCEDURE 7
Tips for proper
installation of display:
Please press all buttons on display
board to make sure display functions
properly.
PROCEDURE 8
PROCEDURE 9
DIAGNOSIS 7