CHECK AND TEST 1
DIAGNOSIS 1
CHECK AND TEST 2
Check to see if the terminal is connected well or not.
Attach magnetic bar to magnetic switch.
Use multimeter to test the resistance value.
Take note of the value.
DIAGNOSIS 2
Result 0 depends on the multimeter
measure range.
The
recommended range for
multimeter is at least 2K
ohms.
PROCEDURE 2
Carefully place switch in trough to avoid damage.
Insert the pin into buckle.
Push the cover in.
CHECK AND TEST 3
Open fridge door and freezer door on same side to same degree for 5 seconds.
DIAGNOSIS 3
CHECK AND TEST 4
DIAGNOSIS 4
Please make sure to test
2 magnetic bars:
one on left side, the
other on right side.
PROCEDURE 3
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Unscrew 3 bolts and remove the top hinge.
Remove fridge door.
Loosen the middle hinge and remove it.
Remove freezer door and replace with new one.
PROCEDURE 4
Don’t forget to add washer onto hinge pin.
When installing door on the hinge, please check to ensure proper alignment of door stopper and hinge.
Ensure gasket is attached properly.
Gaps between door must be even and equal.
Make sure the gasket plate rotates properly when door is opened or closed.
DIAGNOSIS 5