CHECK AND TEST 1

Step 1

testo testo

Step 2

Check carefully to see if gasket is deformed.

DIAGNOSIS 1

PROCEDURE 1

Step 1

Pull gasket out from corner.

PROCEDURE 2

Tip 1

Start from corner

Tip 2

Make sure base of gasket is pressed into trough completely.


Tip 3

Make sure gasket is properly aligned with edges of trough.

Tip 4

After closing the door, make sure gasket is well-attached.

CHECK AND TEST 2

Step 1

Blow hot air on gasket with a hair dryer to soften gasket, so it can be easily attached to cabinet.

Step 2

To assess whether rework was successful, place a torch on shelf and point light towards gasket.

Step 3

Close door to see if there is any light leaking out.

DIAGNOSIS 2

CHECK AND TEST 3

Step 1

Check to make sure that gasket is not wrinkling.

DIAGNOSIS 3

CHECK AND TEST 4

Step 1

Use vernier callipers
to measure width of entrance of gasket seat.

Step 2

Use tool of same shape as gasket seat and insert into gasket seat, then flip the tool around.

DIAGNOSIS 4

PROCEDURE 3

Step 1

Unscrew hinge cover.

Step 2

Remove the cover.

Step 3

Disconnect the terminals.

Step 4

Unscrew 3 bolts and remove the top hinge.

Step 5

Remove fridge door.

Step 6

Unscrew 3 bolts and remove the middle hinge.

Step 7

Take away bottom door.

Note


CHECK AND TEST 5

Step 1

Make sure gasket is not detaching.

Step 2

Insert the gasket into gasket seat, and pull it with a force of 30Nm.

DIAGNOSIS 5

PROCEDURE 4

Tip 1

Don’t forget to add washer onto hinge pin.

Tip 2

When installing door on hinge, please make sure door-stopper and hinge are properly aligned.

Tip 3

Make sure gasket is attached properly.

Tip 4

Make sure gaps between doors are even.

Tip 5

Check to make sure gasket plate turns over properly when door is opened and closed.

CHECK AND TEST 6

Step 1

Blow hot air on gasket with a hair dryer to soften gasket, so it can be easily attached to cabinet.

Step 2

To assess whether rework was successful, place a torch on shelf and point light towards gasket.

Step 3

Close door to see if there is any light leaking out.

DIAGNOSIS 6