PROCEDURE 1
Cut off exhaust pipe and suction pipe.
Power up the compressor and feel the exhaust pressure from the exhaust pipe with a piece of paper.
DIAGNOSIS 1
CHECK AND TEST 2
Braze the joints of
suction and exhaust
pipes.
1) Melt brazing material
with flame and pull
out processing tube
using a pair of pliers.
2) Re-braze a copper
tube onto compressor
processing tube.
To get more details on
brazing requirements,
please go to Annex B1
Replace the filter.
1) Clean paint from
brazed joint of
drying-filter.
2) Cut off drying-filter.
3) Cut off capillary and
shake to remove the
cut end.
4) Braze on a new
drying-filter.
Joint points 4,5,7,9
have been replaced by
exchanging pipe and
filter.
Now check 1, 6, 13, and
14. Take joint one for
example.
1) First, cut off end
closed to exhaust end
(A in below picture).
2) Then, cut off the end
closed to suction end.
DIAGNOSIS 2
PROCEDURE 2
Use a larger copper tube to connect 2 ends of brazed joint.
Click below link to get more details for vocuuming and gas-charging requirements, go to Annex B2
Block processing pipe
twice with locking pliers.
DIAGNOSIS 2