PROCEDURE 1
CHECK AND TEST 1
Cut off capillary to discharge refrigerant.
Discharge all refrigerant toward the exhaust vent.
Cut off exhausting pipe.
Power up the compressor and feel the exhaust pressure from the exhausting pipe with a piece of paper.
DIAGNOSIS 1
CHECK AND TEST 2
Braze the joints of suction and exhaust pipes.
Exchange the filter.
For the purpose of
example, examine joint 1:
a) First, cut off end
closed to exhaust end
(A in below picture).
b) Then, cut off the end
closed to suction end.
DIAGNOSIS 2
PROCEDURE 2
Use a larger copper tube to connect 2 ends of brazed joint.
Block processing pipe twice by locking pliers.
DIAGNOSIS 3