CHECK AND TEST 1
Check if pipes touch each other or not.
Check if pipes touch compressor niche or not.
Check if pipes touch drain pipe or drain tray or not.
DIAGNOSIS 1
CHECK AND TEST 2
Check if evaporative condenser tube is well- attached to water tray or not.
DIAGNOSIS 2
CHECK AND TEST 3
Shake the tray, check if it is loose or not.
DIAGNOSIS 3
PROCEDURE 1
Unscrew.
Move evaporating pipe up.
Push the tray in to loosen it from buckle and move tray up to take it out.
REVERSE STEPS ABOVE TO INSTALL WATER TRAY, PAY ATTENTION TO THE KEY POINTS BELOW
Make sure the hook is fixed onto edge of holder plate edge firmly.
CHECK AND TEST 4
Check whether pipe is resonating noisily.
DIAGNOSIS 6