CHECK AND TEST 1

Step 1

Power on the appliance, and start manual defrost.

Case 1:

OUTSIDE DISPLAY

a) Press FREEZER button together with MODE button and hold for 5 seconds. Alarm will sound, freezer temperature shows 0 and flashes.

b) Then touch FREEZER button continuously, freezer temperature
will display 0, 1 and 3 in a loop.

c) When freezer temperature displays 3, stop touching and manual defrost is selected.

Case 2:

INTERNAL TOP CONTROLLER

a) Press TEMP button together with MODE button and hold for 5 seconds. Alarm will sound, freezer temperature shows 0 and flashes.

b) Then press Temp button continuously, temperature will display 0, 1 and 3 in a loop;

c) When temperature displays 3, stop pressing and manual defrost is selected.

Note


Step 2

Unscrew cover of mainboard with a Cross-head screwdriver.

Step 3

Test voltage of terminals for defrost heater using multimeter.

Step 4

Take note of the result and then power off to quit manual defrost.

 

DIAGNOSIS 1


PROCEDURE 1


Step 1

Unscrew cover of mainboard with a Cross-head screwdriver.

Step 2

Disconnect terminals.

Step 3

Prize off earthing wires.

Step 4

Unscrew the mainboard.

Step 5

Prize off the buckle to remove mainboard.

Reverse steps above to install a new mainboard.

CHECK AND TEST 2