8.5 RELIABILITY FAULTS:
DOOR STOPPER IS BROKEN
CHECK AND TEST 1
Push the door to an angle of 8° from cabinet, if the door doesn’t close automatically, there is a problem with the door stopper.
Check the alignment between door stopper and hinge to find out root causes.
Check to see whether screw is screwed correctly into final position. If not,
this would cause misalignment between door stopper and hinge.
Check if there are too many washers, causing misalignment between door stopper and hinge.
Check if the door stopper is deformed and causing misalignment.
DIAGNOSIS 1
PROCEDURE 1
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Unscrew bolts and remove the top hinge.
Remove upper door.
Unscrew 3 bolts and remove the middle hinge.
Remove lower door.
Tilt cabinet.
Unscrew the adjustable foot.
Unscrew the adjustable foot.
Reverse procedures above to install the door, please pay attention to the key points below.
Don’t forget to add washer onto hinge pin.
When installing door onto hinge, please check the match between door- stopper and hinge.
Make sure gasket is attached well.
Make sure gaps between doors are even.