NOTE


CHECK AND TEST 1

Step 1

Plug off the product. If LED is off, the appliance is switched off.

PROCEDURE 1

Step 1

Unscrew LED cover.

Step 2

Remove LED cover. 

Step 3

 Unscrew thermostat cover.

Step 4

Lever off the buckle and push the thermostat out.

Step 5

Disconnect terminal for LED.

Step 6

Disconnect terminal for thermostat.

Step 7

Pull capillary out from hole.

Step 8

Test thermostat individually

DIAGNOSIS 1

PROCEDURE 2

Tips 1

When inserting capillary into the hole, make sure the first red mark goes in the hole, but second one remains outside of the hole.

Tips 2

When inserting thermostat into the buckle, please push the control knob into the buckle first.

Tips 3

Make sure wires are twisted around screw pole to avoid damaging wires with screw.

DIAGNOSIS 2

Step 1

Set the knob of thermostat to gear Max-1, and switch on the appliance to do a performance check.

Step 2

 After 40min or 60 min, test the internal temp.

Note

CHECK AND TEST 1

Step 1

Plug off the product. If LED is off, the appliance is switched off.

PROCEDURE 1

Step 1

Remove screw cover.

Step 2

Unscrew the screw.

Step 3

Remove thermostat cover.

Step 4

Pull capillary from the hole.

Step 5

Lever off the knob.

Step 6

Disconnect terminal for thermostat.

Step 7

Test thermostat individually.

DIAGNOSIS 1

PROCEDURE 2

Tip 1

When inserting capillary into the hole, make sure the first red mark on capillary goes into the hole, but second mark remains outside of the hole.

Tip 2

Make sure pins of thermostat cover are properly inserted into the holes.

Tip 3

Make sure wires are pushed into cavity for thermostat.

DIAGNOSIS 2

Step 1

Set the knob of thermostat to gear Max-1, and switch on the appliance to do a performance check.

Step 2

After 40min or 60 min, test the internal temp.