Discharge refrigerant:
1) Use pliers to cut off charging tube.
2) Discharge all refrigerant toward the exhaust vent
Melt brazing material with flame and pull processing tube out with a pair of pliers.
Re-braze a copper tube onto processing tube of compressor.
Please find more details of brazing requirements on 10.4 Annex B1
Install quick connector onto rebrazed pipe.
Cut off exhaust pipe and suction pipe.
Power on the compressor and test exhaust pressure coming from exhaust pipe with a piece of paper.
Test the suction pressure of suction pipe with a piece of paper.
DIAGNOSIS 1
PROCEDURE 1
Unscrew terminal cover.
Remove terminal cover.
Disconnect all terminals.
Unscrew earthing wire.
Unscrew nut of compressor.
Install a new compressor on top.
Weld the joints of suction and exhaust pipes.
PROCEDURE 2
CHECK AND TEST 2