NO-FROST
CROSS 4-DOOR WITH INVERTER COMPRESSOR
CROSS 4-DOOR WITH NORMAL COMPRESSOR
TOP MOUNT WITH INVERTER COMPRESSOR
TOP MOUNT WITH NORMAL COMPRESSOR
TOP MOUNT WITH NORMAL COMPRESSOR
(US Style)
FRENCH 4-DOOR WITH INVERTER COMPRESSOR
FRENCH 4-DOOR WITH NORMAL COMPRESSOR
COMBI WITH NORMAL COMPRESSOR
COMBI WITH INVERTER COMPRESSOR
COMBI WITH NORMAL COMPRESSOR E-DAMPER
SIDE BY SIDE WITH INVERTER COMPRESSOR
SIDE BY SIDE WITH NORMAL COMPRESSOR
SINGLE-DOOR FREEZER
(EU Style)
SINGLE-DOOR FREEZER
(US Style)
SINGLE-DOOR LARDER
(EU Style)
DEFROST
COMBI
TOP MOUNT
CHEST FREEZER
SINGLE-DOOR FRIDGE
SINGLE-DOOR FREEZER
SINGLE-DOOR LARDER
BUILT-IN COMBI
BUILT-IN TOP MOUNT
BUILT-IN ELECTRONIC SINGLE-DOOR LARDER
BUILT-IN ELECTRONIC SINGLE-DOOR FRIDGE
BUILT-IN MECHANIC SINGLE-DOOR LARDER
BUILT-IN MECHANIC SINGLE-DOOR FRIDGE
FROST FREE
COMBI WITH INVERTER COMPRESSOR
COMBI WITH NORMAL COMPRESSOR
SUPPORT
LOG-OUT
CHECK AND TEST 1
Note
Step 1
Discharge refrigerant:
1) Use pliers to cut off charging tube.
2) Discharge all refrigerant toward the
exhaust vent.
Step 2
Melt brazing material with flame and pull processing tube out with a pair of pliers.
Step 3
Re-braze a copper tube onto processing tube of compressor.
Please find more details of brazing requirements on
10.4 Annex B1
.
Note
Step 4
Install quick connector onto rebrazed pipe.
Step 5
Cut off exhaust pipe and suction pipe.
Step 6
Power on the compressor and test exhaust pressure coming from exhaust pipe with a piece of paper.
Step 7
Test the suction pressure of suction pipe with a piece of paper.
Step 3
DIAGNOSIS 1
PROCEDURE 1
Step 1
Unscrew terminal cover.
Step 2
Remove terminal cover.
Step 3
Disconnect all terminals.
Step 4
Unscrew earthing wire.
Step 5
Unscrew nut of compressor.
Step 6
Install a new compressor on top.
Step 7
Braze the joints of suction and exhaust pipes.
PROCEDURE 2
Step 1
Re-braze a copper tube onto processing tube of compressor. To get more details on brazing requirements, please go to
10.4 Annex B1
.
Step 2
Install quick connector onto re-brazed pipe.
Step 3
Clean paint off of brazed joint of drying filter.
Step 4
Cut off the brazed joint of drying filter.
Step 5
Cut off capillary and remove the cut end by shaking.
Step 6
Braze on a new dryingfilter.
Step 7
Inject nitrogen(1.57Mpa) through quick connector into pipe for at least 3 min to blow remaining refrigerant away.
Step 8
Add quick connector onto processing pipe of drying-filter.
Step 9
Perform leakage test on brazed joints of dryingfilter and compressor processing pipe.
Step 10
Vacuum and recharge. Please get more details of vacuuming and gascharging requirements on
10.5 Annex B2
.
Step 11
Block processing pipe twice by locking pliers.
Step 12
Leave locked pliers attached to second block and shake to cut off the remaining pipe.
Step 13
Braze the ends and remove the pliers.
CHECK AND TEST 2
DIAGNOSIS 2