CHECK AND TEST 1
Plug off the product and open the door to let internal temp., warm up to ambient temperature.
Set the knob of thermostat at gear max-1, and plug in to switch on the appliance.
DIAGNOSIS 1
After first stop, please consult table below to find out bulb position, then measure temperature near thermostat bulb.
For visible evaporator
Please find out thermostat bulb position on the surface of evaporator.
DIAGNOSIS 2
TABLE 2
If you have a top thermostat, please follow procedure below.
If you have a side thermostat, please go to link
If you have a thermostat on the side of evaporator, please go to link
If you have a thermostat in the compressor niche, please go to link.
TOP THERMOSTAT
Unscrew LED cover.
Unscrew thermostat cover.
Lever off the buckle and push the thermostat out.
Disconnect terminal for LED.
Disconnect terminal for thermostat.
Pull capillary out from hole.
PROCEDURE 2
When inserting capillary into the hole, make sure the first red mark goes in the hole, but second one remains outside of the hole.
When inserting thermostat into the buckle, please push the control knob into the buckle first.
Make sure wires are twisted around screw pole to avoid damaging wires with screw.
Pull capillary from the hole.
Disconnect terminal for LED.
Disconnect terminal for thermostat.
Unscrew the nut.
PROCEDURE 2
When inserting capillary into the hole, make sure the first red mark goes into the hole, but second one remains outside of the hole.
Make sure the pins of thermostat cover are
inserted into the holes.
Make sure wires are placed into cavity of thermostat.
THERMOSTAT ON THE
SIDE OF EVAPORATOR
Remove the buckle from the groove, and remove the ice-box door.
Unscrew the screw.
Push the thermostat box forward, remove the box.
Disconnect terminal for thermostat.
Disconnect terminal for LED
When inserting capillary into the hole, make sure the bulb of thermostat is in final position.
Make sure the wires are placed into cavity of thermostat.
THERMOSTAT ON THE
COMPRESSOR NICHE
Unscrew.
Prize up thermostat knob and remove.
Prize up the thermostat.
Pull capillary out from the foam.
When inserting capillary into the hole, make sure the bulb of thermostat is in final position.
When inserting thermostat into the hole, please verify that the seal of the hole is good.
Don’t forget to put the wires in the right position and attach a cable tie.
CHECK AND TEST 3
Set the knob of thermostat at gear max-1, and plug in to switch on the appliance.
After first stop, please consult table 1 to find out bulb position, then measure temperature near thermostat bulb.
For visible evaporator
Please find out thermostat bulb postition on the surface of evaporator.