CHECK AND TEST 1

Step 1

Place a torch in cabinet and check to see if light
leaks out from gasket.

Step 2

Blow hot air onto gasket with hair dryer to soften, so that gasket can be easily attached onto cabinet.

DIAGNOSIS 1
PROCEDURE 1

Step 1

Prize up screw cover.

Step 2

Unscrew.

Step 3

Push the top cover forward.

Step 4

Take away the top cover.

Step 5

Unscrew 3 bolts and remove door hinge.

Step 6

Remove the door.

Step 7

Lay down the cabinet and unscrew the adjustable foot.

CHECK AND TEST 2

Case 1:
Light leaks from the corner on opening side.

PROCEDURE 2

Step 1

Unscrew the bottom hinge and move it outward.

Step 2

Use hinge with large hole and push outward.

Step 3

Use hair dryer to blow hot air onto gasket to
soften so that gasket can be easily attached onto cabinet.

Case 2:
Light leakage can be seen from the corner of
door hinge side.

Step 1

Unscrew the bottom hinge and move it
inward.

Step 2

Use hinge with large hole and push inward.

Step 3

Use hair dryer to blow hot air onto gasket to
soften so that gasket can be easily attached onto cabinet.

DIAGNOSIS 2

Step 1

After adjusting hinges, put a torch into cabinet
and check to see if any light leaks out through
gasket.

Case 3:
Light leakage can be seen from the middle.

Step 1

Use steel ruler to measure the deformation
of cabinet.

Step 2

Use steel ruler to measure the deformation
of door.

DIAGNOSIS 3

PROCEDURE 3

Step 1

Prize up screw cover.

Step 2

Unscrew.

Step 3

Push the top cover forward.

Step 4

Take away the top cover.

Step 5

Unscrew 3 bolts and remove door hinge.

Step 6

Remove the door.
PROCEDURE 4

Step 1

Use steel ruler to measure the deformation of door to make sure new door is good before
installation.

Step 2

Use hair dryer to blow hot air onto gasket to
soften so that gasket can be easily attached onto cabinet.

Tip 1

Don’t forget to add washer onto hinge pin (if there is one).

Tip 2

When installing door onto hinge, please check
the alignment between door-stopper and hinge.

Tip 3

Make sure gasket is properly attached.

Tip 4

Make sure the door is parallel to the cabinet.

DIAGNOSIS 4

Step 1

Place a torch in cabinet and check to see if light
leaks out from gasket.