CHECK AND TEST 1
Plug off the product
and open the door to
let internal temperature
warm up to ambient
temperature.
If LED is off, it means the
appliance is switched off.
Set the knob of thermostat at gear max-1, and plug in to switch on the appliance.
DIAGNOSIS 1
CHECK AND TEST
After first stop, please
consult below table to find
out bulb position, then
measure temperature
in the area near the
thermostat bulb.
Refer to below table to find standard cut-in and cut-off temperature of thermostat when set to gear Max-1(such as 6), using Homa model name found on rating label, then compare tested value with standard value.
DIAGNOSIS 2
PROCEDURE 1
Lever off the screw cover.
Unscrew.
Remove thermostat cover.
Pull capillary from the hole.
Disconnect terminal for LED.
Disconnect terminal for thermostat.
Lever off the knob.
Unscrew the nut.
Remove the thermostat.
PROCEDURE 2
When inserting capillary into the hole, make sure the first red mark goes into the hole, but second one remains outside of the hole.
Make sure the pins of thermostat cover are inserted into the holes.
Make sure wires are placed into cavity of thermostat.
CHECK AND TEST 3
Set the knob of thermostat at gear max-1, and plug in to switch on the appliance.
After first stop, please
consult below table to find
out bulb position, then
measure temperature
in the area near the
thermostat bulb.
Refer to below table to find standard cut-in and cut-off temperature of thermostat when set to gear Max-1(such as 6), using Homa model name found on rating label, then compare tested value with standard value.
DIAGNOSIS 3
CHECK AND TEST 4
DIAGNOSIS 4