Note

PROCEDURE 1

Step 1

Remove shelves.

Step 2

Remove crispers.

Step 3

Remove shelf cover

Step 4

Hold the cover and turn in counter-clockwise direction to loosen cover. Then, remove cover.

Step 5

Use 6mm Cross-head screwdriver to loosen the screw.

Step 6

Hold the edge of air duct to remove.


Step 7

Disconnect the terminal for fridge temp. sensor.

CHECK AND TEST 1

Step 1

Connect damper terminal to terminals inside fridge.

Step 2

Unscrew cover of mainboard with a cross- head screwdriver.

Step 3

Offer signal to dampers from terminal in PCB area (between “A+” & “B+” or “A-” & “B-”)

Step 4

An oscilloscope should display a square wave signal.

Step 5

See if door of damper opens gradually.

DIAGNOSIS 1

PROCEDURE 2

Step 1

Unscrew with 6mm Cross-head driver.

Step 2

Remove plastic cover of damper.

Step 3

Lift damper out of air duct in foam.

CHECK AND TEST 2

Step 1

Use a standard signal producer to supply square wave to damper from terminal in fridge area.

DIAGNOSIS 2

CHECK AND TEST 3

Step 1

In duct area, check if terminal is pushed into final position.

Step 2

Check if terminal is filled with foam or not.

IF YES, please use a needle to clean and remove the foam.

Step 3

Check to ensure that wires are in proper order.

IF WIRE ORDER IS WRONG, PLEASE FOLLOW PROCEDURE 3 TO CORRECT THEM.

Step 4

Check to make sure wire order in the foam is right and/or see if it’s been cut off.

Step 5

Use multimeter to test connections.

1. Put detector into one end of wires in PCB area;

2. Put another detector into end of wires behind air duct.



DIAGNOSIS 3


DIAGNOSIS 4


Note


PROCEDURE 3


Step 1

Cut wire off.

Step 2

Peel off the sleeves.

Step 3

Check to ensure proper wire order and reconnect them.

Step 4

Tin soldering.


Step 5

Cover connecting point with electrical tape.


CHECK AND TEST 4

Step 1

Connect damper terminal to terminals inside fridge.


Step 2

Offer signal to dampers from terminal in PCB area (between “A+” & “B+” or “A-” & “B-”)


Step 3

An oscilloscope should display a square wave signal.


Step 4

See if door of damper opens gradually.

DIAGNOSIS 5


PROCEDURE 4


Step 1

Put damper into air duct in foam.


Step 2

Put the plastic cover on top of damper.


Step 3

Connect the terminal.


Step 4

Screw with 6mm cross-head screwdriver.


PROCEDURE 5


Step 1

Re-connect the terminals.


Step 2

Hold air duct by edges to put it back in place.


Step 3

Use a 6 mm cross-head screwdriver to tighten the screw clockwise.


Step 4

Hold the cover and turn it clockwise to tighten
the lid, then pull outwards.

Step 5

Insert shelves.


TIPS DURING INSTALLATION PROCEDURES FOR FRIDGE AIR DUCT.

Tip 1

Connect the terminals.


Tip 2

Push terminals into place, then move wires to prevent crushing of wires with edge of air duct.


Tip 3

When reinstalling the air duct, first insert positive shaft into the negative hole.


Tip 4

Then, fasten the clasp on top using the same method.


DIAGNOSIS 6

Step 1

Power on the appliance, then open the door and press the mechanical switch pin, put your hand in front of fridge air duct outlet to verify.