CHECK AND TEST 1
Unscrew cover of mainboard with a cross-head screwdriver.
Press and hold freezer button for a long time.
Later 1 and 3 appear in freezer temperature area.
1 means:
start forced cooling.
3 means:
start manual defrost.
When 3 appears, remove finger and select manual defrost.
Test voltage of defrost heater terminals as shown in picture.
WARNING! HIGH VOLTAGE!
Take note of result. Then, remove plug off to quit manual defrost.
DIAGNOSIS 1
PROCEDURE 1
Disconnect terminals.
Pull out earthing wires.
Unscrew the mainboard.
Pull out the buckle to remove the mainboard.
PROCEDURE 2
CHECK AND TEST 2
Press and hold freezer button for a long time.
Later 1 and 3 appear in freezer temperature area.
1 means:
start forced cooling.
3 means:
start manual defrost.
When 3 appears, remove finger and select manual defrost.
Test voltage of defrost heater terminals as shown in picture.
WARNING! HIGH VOLTAGE!
Take note of result. Then, remove plug off to quit manual defrost.
DIAGNOSIS 2