8.11 RELIABILITY FAULTS:

  BALCONIES ARE NOT ATTACHED PROPERLY

DIAGNOSIS 1


CHECK AND TEST 1

Step 1

Check whether balcony detaches when bottle is removed.

Step 2

Reworking method.
Add pieces of plastic to strengthen fastening.

Note


PROCEDURE 1


Step 1

Unscrew hinge cover.

Step 2

Remove the cover.

Step 3

Disconnect the terminals.

Step 4

Unscrew 3 bolts and remove the top hinge.

Step 5

Remove upper door.

PROCEDURE 2


Tip 1

Don’t forget to add washer onto hinge pin.

Tip 2

When installing door onto hinge, please check the match between door- stopper and hinge.

Tip 3

Make sure gasket is attached well.

Tip 4

Make sure gaps between doors are even.

Tip 5

Check whether the gasket plate can be turned over normally when the door is opened or closed.