PROCEDURE 1
Remove shelves.
Remove crispers.
Remove shelf cover
Hold the cover and turn in counter-clockwise direction to loosen cover. Then, remove cover.
Use 6mm Cross-head screwdriver to loosen the screw.
Hold the edge of air duct to remove
Disconnect the terminal for fridge temp. sensor.
CHECK AND TEST 1
Connect damper terminal to terminals inside fridge.
Unscrew cover of mainboard with a cross- head screwdriver.
Offer signal to dampers from terminal in PCB area (between “A+” & “B+” or “A-” & “B-”)
An oscilloscope should display a square wave signal.
DIAGNOSIS 1
PROCEDURE 2
Unscrew with 6mm Cross-head driver.
Remove plastic cover of damper.
Lift damper out of air duct in foam.
CHECK AND TEST 2
Use a standard signal producer to supply square wave to damper from terminal in fridge area.
DIAGNOSIS 2
CHECK AND TEST 3
In duct area, check if terminal is pushed into final position.
Check if terminal is filled with foam or not.
Check to ensure that wires are in proper order.
IF WIRE ORDER IS WRONG, PLEASE FOLLOW PROCEDURE 3 TO CORRECT THEM.
Check to make sure wire order in the foam is right and/or see if it’s been cut off.
Use multimeter to test connections.
DIAGNOSIS 3
DIAGNOSIS 4
PROCEDURE 3
Cut wire off.
Peel off the sleeves.
Check to ensure proper wire order and reconnect them.
Tin soldering.
Cover connecting point with electrical tape.
CHECK AND TEST 4
Connect damper terminal to terminals inside fridge.
Offer signal to dampers from terminal in PCB area (between “A+” & “B+” or “A-” & “B-”)
An oscilloscope should display a square wave signal.
DIAGNOSIS 5
PROCEDURE 4
Put damper into air duct in foam.
Put the plastic cover on top of damper.
Connect the terminal.
Screw with 6mm cross-head screwdriver.
PROCEDURE 5
Re-connect the terminals.
Hold air duct by edges to put it back in place.
Use a 6 mm cross-head screwdriver to tighten the screw clockwise.
Hold the cover and turn it clockwise to tighten the lid, then move it backwards.
Insert shelves.
TIPS DURING INSTALLATION PROCEDURES FOR FRIDGE AIR DUCT.
Connect the terminals.
Push terminals into place, then move wires to prevent crushing of wires with edge of air duct.
When reinstalling the air duct, first insert positive shaft into the negative hole.
Then, fasten the clasp on top using the same method.
DIAGNOSIS 6
Power on the appliance, then open the door and press the mechanical switch pin, put your hand in front of fridge air duct outlet to verify.