COMPONENT:
GASKET PLATE
CHECK AND TEST 1
Open left fridge door to see if gasket plates turns up and down automatically.
DIAGNOSIS 1
CHECK AND TEST 2
Place a torch on shelf with light pointed towards the gasket.
DIAGNOSIS 2
CHECK AND TEST 3
Blow hot air on gasket with a hair dryer to soften gasket, so it can be easily attached to cabinet.
Place a torch on shelf with light pointed towards the gasket.
Close the door again to see if any light is visible from interior.
If light still leaks out from internal, place the front edge of a steel ruler parallel to the gasket plate. Then, measure the gap between the ruler and the plate.
DIAGNOSIS 3
PROCEDURE 1
Remove the screw cover in the middle.
Loosen 2 screws
of terminal cover in
anticlockwise direction.
Disconnect the terminal.
Use 2 hands to move gasket plate up.
Lift gasket plate up until negative end is released from positive end of fastener.
PROCEDURE 2
Connect the terminals then place wires carefully so they will not be crushed by cover.
Check to make sure gasket plate can turn properly up and flat when doors are opened and closed.
CHECK AND TEST 4
To assess whether rework was successful, place a torch on shelf with light pointed towards the gasket.
Close the door to see if any light is visible from interior.
DIAGNOSIS 4
CHECK AND TEST 5
Place torch in the cabinet and check to see if any light leaks out through gasket.
If any light leaks out through gasket, blow hot air on gasket with a hair dryer to soften gasket, so it can be easily attached to cabinet.
DIAGNOSIS 5
PROCEDURE 3
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Unscrew 3 bolts and remove the top hinge.
Remove fridge door.
Unscrew 3 bolts and remove the middle hinge.
CHECK AND TEST 6
Light leaks out from the corner of opening side.
Note
Add washer to make middle hinge move outward.
Use hinge with big hole and push it out.
Use a hair dryer to blow hot air onto gasket and make it easier to attach to cabinet.
Light leaks from the corner on hinge side.
Remove washer to make middle hinge move inward.
Push top hinge in.
Use a hair dryer to blow hot air onto gasket and make it easier to attach to cabinet.
DIAGNOSIS 6
CHECK AND TEST 7
Light leaks in the middle of hinge or opening side.
Use steel ruler to measure the deformation of door and cabinet.
Use steel ruler to measure the deformation of door and cabinet.
DIAGNOSIS 7
Don’t forget to put washer on hinge pin.
When inserting door on hinge, please check alignment of door- stopper and hinge.
Gasket must be well-attached.
Gaps between door must be even and equal.
Check to make sure the gasket plate turns over properly when the door is opened and closed.