COMPONENT:

GASKET PLATE

CHECK AND TEST 1

Step 1

Open left fridge door to see if gasket plates turns up and down automatically.


DIAGNOSIS 1


CHECK AND TEST 2

Step 1

Place a torch on shelf with light pointed towards the gasket.


Step 2

Close the door to see if any light is visible from
interior.


DIAGNOSIS 2


CHECK AND TEST 3

Step 1

Blow hot air on gasket with a hair dryer to soften gasket, so it can be easily attached to cabinet.

Step 2

Place a torch on shelf with light pointed towards the gasket.

Step 3

Close the door again to see if any light is visible from interior.

Step 4

If light still leaks out from internal, place the front edge of a steel ruler parallel to the gasket plate. Then, measure the gap between the ruler and the plate.


DIAGNOSIS 3


PROCEDURE 1


Step 1

Remove the screw cover in the middle.


Step 2

Loosen 2 screws
of terminal cover in anticlockwise direction.


Step 3

Disconnect the terminal.


Step 4

Use 2 hands to move gasket plate up.


Step 5

Lift gasket plate up until negative end is released from positive end of fastener.


PROCEDURE 2


Tip 1

Connect the terminals then place wires carefully so they will not be crushed by cover.


Tip 2

Check to make sure gasket plate can turn properly up and flat when doors are opened and closed.


CHECK AND TEST 4

Step 1

To assess whether rework was successful, place a torch on shelf with light pointed towards the gasket.


Step 2

Close the door to see if any light is visible from interior.


DIAGNOSIS 4


CHECK AND TEST 5

Step 1

Place torch in the cabinet and check to see if any light leaks out through gasket.


Step 2

If any light leaks out through gasket, blow hot air on gasket with a hair dryer to soften gasket, so it can be easily attached to cabinet.


DIAGNOSIS 5


PROCEDURE 3

Note

When adjustment is required, please
disassemble hinge and fridge door first.


Step 1

Unscrew hinge cover.


Step 2

Remove the cover.


Step 3

Disconnect the terminals.


Step 4

Unscrew 3 bolts and remove the top hinge.

Step 5

Remove fridge door.


Step 6

Unscrew 3 bolts and remove the middle hinge.


CHECK AND TEST 6


Case 1:

Light leaks out from the corner of opening side.



Note

Step 1

Add washer to make middle hinge move outward.


Step 2

Use hinge with big hole and push it out.


Step 3

Use a hair dryer to blow hot air onto gasket and make it easier to attach to cabinet.


Case 2:

Light leaks from the corner on hinge side.


NOTE


Step 1

Remove washer to make middle hinge move inward.


Step 2

Push top hinge in.


Step 3

Use a hair dryer to blow hot air onto gasket and make it easier to attach to cabinet.


DIAGNOSIS 6


CHECK AND TEST 7

Case 3:

Light leaks in the middle of hinge or opening side.


Step 1

Use steel ruler to measure the deformation of door and cabinet.


Step 2

Use steel ruler to measure the deformation of door and cabinet.


DIAGNOSIS 7


PROCEDURE 4


Tip 1

Don’t forget to put washer on hinge pin.


Tip 2

When inserting door on hinge, please check alignment of door- stopper and hinge.


Tip 3

Gasket must be well-attached.


Tip 4

Gaps between door must be even and equal.


Tip 5

Check to make sure the gasket plate turns over properly when the door is opened and closed.