CHECK AND TEST 1
Unscrew cover of
mainboard with a
cross-head screwdriver.
In mainboard area, check if terminal is pushed into proper final position.
In mainboard area, check if terminal is filled with foam.
If so, use tweezers to
remove foam.
DIAGNOSIS 1
CHECK AND TEST 2
Turn power output of transformer to DC 12V.
Supply power from terminal in PCB area (FAN & GND).
DIAGNOSIS 2
PROCEDURE 1
Remove the upper freezer drawer.
Remove the upper freezer drawer. Remove the upper freezer drawer.
Remove the middle glass shelf located between upper and bottom freezer drawer compartments.
Step 4
Unscrew air duct.
Check the freezer air
duct to find the three
screw covers.
Step 5
Remove the screw covers (total of three) on the air duct with slotted screw driver.
Unscrew all three screws with Cross-head screw driver.
Dismantle the air duct.
Catch the bottom of air
duct.
Pull air duct out from the bottom of air duct.
Pay attention to the connectors when pulling out the air duct.
When re-installing the air duct, move the wires out of the way so that they won’t be crushed by air duct.
After pushing air duct into position, it should make a click sound. If no click is heard, do it again.
CHECK AND TEST 2
In duct area, check if terminal is pushed into final position.
A & C are not OK; B is OK..
Check if terminal is filled with foam or not.
IF YES, please use a needle to clean and remove the foam.
Later, reconnect the terminals
Power off the appliance and turn the power output of transformer to DC 12V.
Supply power from terminal in PCB area.
DIAGNOSIS 2
Check to see if the wires
are in the correct order
and their connections in
the foam are correct:
1. Set multimeter to
resistance gear;
2. Put detector into one end of wires in PCB area;
3. Put another detector into end of wires behind air duct.
DIAGNOSIS 3
DIAGNOSIS 4
PROCEDURE 2
Cut wire off.
Peel off the sleeves.
Check to ensure proper wire order and connect them.
Tin soldering.
Cover connection with electrical tape.
CHECK AND TEST 4
Set output of transformer to DC 12V to test fan from the terminal behind the air duct.
Use power source to test fan from terminal in the back of air duct.
DIAGNOSIS 5
When re-installing the air duct, move the wires out of the way so that they won’t be crushed by air duct.
After pushing air duct into position, it should make a click sound. If no click is heard, do it again.
CHECK AND TEST 5
Open fridge door and freezer drawer, press the mechanical switch.
DIAGNOSIS 6