CHECK AND TEST 1
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Check to see whether sleeves of wires in gasket plate and hinge cover are broken.
Check if earthing wires are loose.
DIAGNOSIS 1
PROCEDURE 1
Cut off the wire.
Peel off the sleeves.
Make sure wires are in proper order and connect them.
Tin soldering.
Cover connecting point with electrical tape.
CHECK AND TEST 2
Power on and perform a
leakage test.
Put one detector on
earthing wire of socket,
and another detector
on edge of side panel without paint.
DIAGNOSIS 2
PROCEDURE 2
Remove central screw cover.
Loosen 2 screws
of terminal cover in
anticlockwise direction.
CHECK AND TEST 3
Check if the wires in gasket plate are broken or not.
DIAGNOSIS 3
PROCEDURE 3
Cut off the wire.
Peel off the sleeves.
Make sure wires are in proper order and connect them.
Tin soldering.
Cover connecting point with electrical tape.
CHECK AND TEST 4
Power on and perform a
leakage test.
Put one detector on
earthing wire of socket,
and another detector
on edge of side panel without paint.
DIAGNOSIS 4
PROCEDURE 4