8.11 RELIABILITY FAULTS:
BALCONIES ARE NOT ATTACHED PROPERLY
DIAGNOSIS 1
CHECK AND TEST 1
Check whether balcony detaches when bottle is removed.
Reworking method.
Add pieces of plastic to
strengthen fastening.
PROCEDURE 1
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Unscrew 3 bolts and remove the top hinge.
Remove upper door.
Don’t forget to add washer onto hinge pin.
When installing door onto hinge, please check the match between door- stopper and hinge.
Make sure gasket is attached well.
Make sure gaps between doors are even.
Check whether the gasket plate can be turned over normally when the door is opened or closed.