CHECK AND TEST 1
Unscrew.
Remove the mainboard cover.
Check if terminal is pushed into final position.
Check to see if terminal is full of foam.
If so, use tweezers to remove foam.
Use multimeter to measure resistance value.
Record the value.
Test temperature on air duct close to sensor.
Use tested temperature to find out the reference resistance in following chart.
DIAGNOSIS 1
PROCEDURE 1
Take out the shelves.
Unscrew the 4 screws.
Hold the bottom of air duct and pull it out.
Disconnect the terminal of fan motor.
Remove air duct.
CHECK AND TEST 2
Step 1
Check to see if sensor is in right position.
DIAGNOSIS 2
PROCEDURE 2
Cut wire off from broken area.
Check to ensure proper wire order and connect
them.
Tin soldering.
Cover connection with electrical tape.
CHECK AND TEST 4
Step 1
Test resistance of sensor.
Measure the temperature of sensor.
CHECK AND TEST 5
Connect the 2 ends in PCB ends.
DIAGNOSIS 5
Before installing the air duct, please tie all wires
together.
Insert left side first, then other side. Make sure
the cavity on the side is aligned with the ribs on
inner liner.
Check to see if there is a wide gap between air
duct and cabinet. If so, install air duct again.