CHECK AND TEST 1

Step 1

Unscrew. 

Step 2

Remove the mainboard cover. 

Step 3

Check if terminal is pushed into final position.

Step 4

Check to see if terminal is full of foam.
If so, use tweezers to remove foam.

Step 5

Use multimeter to measure resistance value. 

Step 6

Record the value. 

Step 7

Test temperature on air duct close to sensor.
Use tested temperature to find out the reference resistance in following chart. 

DIAGNOSIS 1


PROCEDURE 1


Step 1

Pull out the drawers. 

Step 2

Take out the shelves.

Step 3

Unscrew the 4 screws.

Step 4

Hold the bottom of air duct and pull it out.

Step 5

Disconnect the terminal of fan motor.

Step 6

Remove air duct. 

CHECK AND TEST 2

Step 1
Check to see if sensor is in right position.


DIAGNOSIS 2


CHECK AND TEST 3

Step 1
Check to ensure if sensor wires have been
cut off.

DIAGNOSIS 3

PROCEDURE 2

Step 1

Cut wire off from broken area.

Step 2

Peel off the sleeves.

Step 3

Check to ensure proper wire order and connect
them.

Step 4

Tin soldering.

Step 5

Cover connection with electrical tape.

CHECK AND TEST 4

Step 1
Test resistance of sensor.

Step 2

Read the value.

Step 3

Measure the temperature of sensor.

DIAGNOSIS 4

CHECK AND TEST 5

Step 1

Connect the 2 ends in PCB ends.

Step 2

Test connection.

DIAGNOSIS 5

PROCEDURE 3

Tip 1

Before installing the air duct, please tie all wires
together.

Tip 2

Before installing the air duct, please fix cord of
fan well.
Tip 3

Insert left side first, then other side. Make sure
the cavity on the side is aligned with the ribs on
inner liner.

Tip 4

Check to see if there is a wide gap between air
duct and cabinet. If so, install air duct again.