8.6 RELIABILITY FAULTS:

DOOR STOPPER IS BROKEN

CHECK AND TEST 1

Step 1

Push the door to a position with angle of
8o from cabinet, if the door doesn’t close
automatically, there is a problem with the door
stopper.

Step 2

Check the alignment between door stopper
and hinge to find out root causes.

Step 3

Check if bottom hinge is deformed and cause
misalignment.

Step 4

Check if door stopper is deformed and cause
misalignment.

DIAGNOSIS 1


PROCEDURE 1


Step 1

Unscrew hinge cover.

Step 2

Remove the cover.

Step 3

Disconnect the terminals.

Step 4

Unscrew 3 bolts and remove the top hinge.

Step 5

Remove the door.


 

Step 6

Lay down product so that compressor is resting on foam.

Step 7

Unscrew 4 bolts and remove bottom hinge.

Step 8

Unscrew 2 screws and remove door stopper.

PROCEDURE 2


Tip  1

When installing door onto hinge, please check
the alignment between door-stopper and hinge.

Tip 2

Make sure gasket is attached well.

Tip  3

Make sure gaps between doors are even.