8.7 RELIABILITY FAULTS:
HINGE IS DAMAGED
CHECK AND TEST 1
DIAGNOSIS 1
PROCEDURE 1
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Unscrew 3 bolts and remove the top hinge.
Remove the door.
Tilt cabinet by 10
degrees.
Unscrew 4 bolts and remove bottom hinge.
CHECK AND TEST 2
Check if the hinges are deformed or cracked,
or whether screws are loose.
DIAGNOSIS 2
When installing door onto hinge, please check
the alignment between door-stopper and hinge.
Make sure gasket is attached well.
Make sure gaps between doors are even.