CHECK AND TEST 1
Unscrew cover of mainboard with a Cross-head screwdriver.
In PCB area, check if terminal is inserted to final position. If not, reinsert it to final position.
Measure resistance of heater from terminal in PCB area.
Check the result.
Remove all shelves.
Remove upper drawers.
Remove bottom drawer.
Remove drawer cover.
Remove glass shelves under drawers.
Prize off the decorative panel and take if off.
Unscrew the upper air duct.
Pull outward and take off the upper air duct.
Unscrew the lower airduct.
Disconnect the connectors between airduct and cabinet.
Remove the lower air duct.
CHECK AND TEST 2
Check if terminal is pushed properly into final position.
Measure resistance of heater from terminal in freezer.
DIAGNOSIS 2
PROCEDURE 2
Disconnect terminal of heaterStep
Unscrew the two screws with 6mm cross-head screwdriver.
Cut off the fastening strap .
Take out the holding foam.
Loosen heater fastening clips.
Lift evaporator with heater up 20mm. Bottom of evaporator must be higher than the edge of water trough.
Remove the heater
Reverse steps above to reinstall the heater and pay attention to the key points below
Do not damage the wires of the heater while installing the new heater.
CHECK AND TEST 3
Set multimeter to resistance gear.
Put detector into one end of wires in PCB area. Put another detector into end of wires behind air duct.
CHECK AND TEST 4
Put your hand close to defrost heater.
DIAGNOSIS 4