CHECK AND TEST 1
Unscrew cover of mainboard with a Cross-head screwdriver.
Check if terminal in PCB area is pushed to final position. If not, reinsert it to final position.
Set multimeter to
resistance gear.
In PCB area, measure the resistance of defrost temp. sensor with a multimeter.
Take note of the result.
Measure the temperature
of freezer air duct, near the
defrost temp. sensor.
Use measured temperature
to find the standard
resistance value in
Temperature-Resistance
Chart for Sensor.
DIAGNOSIS 1
PROCEDURE 1
Remove all shelves.
Remove upper drawers.
Remove bottom drawer.
Remove drawer cover.
Disconnect the terminal
of fan motor.
Prize off the decorative panel and take if off.
Step 7
Unscrew the upper air
duct.
Pull outward and take off
the upper air duct.
Unscrew the lower
airduct.
Disconnect the connectors between airduct and cabinet
Remove the lower air duct.
CHECK AND TEST 2
Check if terminal is
pushed properly into final
position.
Check if sensor is attached in proper position, as shown in picture. If not, correct it.
Check if wire of defrost
sensor is broken.
If yes, replace it with a
new one.
Check if the terminal is stuffed with foam.
Measure the temperature of defrost temp. sensor.
DIAGNOSIS 2
CHECK AND TEST 3
Set multimeter to resistance gear.
Put detector into one end of wires in PCB area. Put another detector into end of wires behind air duct.
DIAGNOSIS 2