PROCEDURE 1

Note

Entrance of drain pipe is covered by freezer air duct, you need to disassemble freezer air duct and remove evaporator to check it.

Step 1

Remove all shelves.

Step 2

Remove upper drawers.

Step 3

Remove bottom drawer.

Step 4

Remove drawer cover.

 



Step 5

Remove glass shelves under drawers.

Step 6

Prize off the decorative panel and take if off.

Step 7

Unscrew the upper air duct.

Step 8

Pull outward and take off the upper air duct.

Step 9

Unscrew the lower airduct.

Step 10

Disconnect the connectors between airduct and cabinet.  

Step 11

Remove the lower air duct.

CHECK AND TEST 1

Step 1

Check if drain pipe is blocked with ice or foam.

DIAGNOSIS 1

Case 1:

Drian pipe is blocked with foam.

Use metal rod with tip head to smash foam in drain pipe.

Case 2:

Drain pipe is blocked with ice.

Blow hot air to melt the ice, and then add a heat- conducting wire between defrost heater and drain hole.

PROCEDURE 2

Tip 1

Make sure the sealing sponges are in good condition.

Tip 2

When reinstalling the air duct, fasten the wires to avoid crushing with air duct.

Tip 3