CHECK AND TEST 1
PROCEDURE 1
Remove all shelves.
Remove upper drawers.
Remove bottom drawer.
Remove drawer cover.
Remove glass shelves
under drawers.
Prize off the decorative panel and take if of
Unscrew the upper air duct.
Pull outward and take off the upper air duct.
Unscrew the lower airduct.
Disconnect the connectors between airduct and cabinet.
Remove the lower air duct.
CHECK AND TEST 2
Check fan blade is broken or not.
Shake fan blade to check if fan is loose.
Supply DC 12V power to fan to check if there any clash.
DIAGNOSIS 2
PROCEDURE 2
Make sure the sealing sponges are in good condition.
When reinstalling the air duct, fasten the wires to avoid crushing with air duct.
Check to see if there is a wide gap between air duct and cabinet. If there is, reinstall air duct.