PROCEDURE 1
Internal wires for defrost heater is covered by freezer air duct, you need to disassemble
freezer air duct to check it.
Remove all shelves.
Remove upper drawers.
Remove bottom drawer.
Remove drawer cover.
Remove glass shelves
under drawers.
Prize off the decorative panel and take if off.
Unscrew the upper air
duct.
Pull outward and take off the upper air duct.
Unscrew the lower airduct.
Disconnect the connectors between airduct and cabinet.
Remove the lower air duct.
CHECK AND TEST 1
Check if wires of defrost heater are broken or not.
DIAGNOSIS 1
PROCEDURE 2
Disconnect terminal of heater.
Unscrew the two screws with 6mm Philips driver.
Cut off the fastening strap.
Take out the holding foam.
Loosen heater fastening clips.
Lift evaporator with heater up 20mm. Bottom of evaporator must be higher than the edge of water trough.
Remove the heater.
Reverse steps above to reinstall the heater.
WARNING:
Make sure not to
deform pipes in red
square below during
step 5 to step 7.
CHECK AND TEST 2
Power on the appliance and perform a leakage test.
DIAGNOSIS 2
Make sure the sealing sponges are in good condition.
When reinstalling the air duct, fasten the wires to avoid crushing with air duct.
Check to see if there is a wide gap between air duct and cabinet. If there is, reinstall air duct.