CHECK AND TEST 1
Unscrew cover of mainboard with a Cross-head screwdriver.
Check if terminal is inserted to final position
in PCB area.
Check if wire order for LED is right or not in
PCB area.
Right picture shows the correct condition.
Check if wire order is correct, or if terminal
is filled with foam.
Use tweezers to pick foam out and insert the
terminal into its position again.
DIAGNOSIS 1
GENERAL PROCEDURES
FOR RECONNECTING
INTERNAL WIRES.
Cut wire off.
Peel off the sleeve
Check to ensure proper wire order and reconnect them.
Tin soldering.
Cover connecting point with electrical tape.
CHECK AND TEST 2
Power on the appliance,
open fridge door, check
if LED light is on or not.
Press down the mechanical switch,
check if LED light is off or not.
DIAGNOSIS 2
PROCEDURE 1
LED LIGHT WITHOUT CONTROL BOARD
Prize off the cover with 2mm slotted driver.
Unscrew with 6mm Philips screwdriver.
Pull down the lamp box.
Disconnect the terminal.
Loosen the clips and take off the LED lamp.
CHECK AND TEST 3
Provide DC12V to LED on the top to check if it is on or not.
DIAGNOSIS 3
CHECK AND TEST 4
Set multimeter to resistance gear.
Check wire connection from PCB area to LED
area.
DIAGNOSIS 4