8.5 RELIABILITY FAULTS:

DOOR STOPPER IS BROKEN

CHECK AND TEST 1

Step 1

Push the door to an angle of 8° from cabinet,
if the door doesn’t close automatically, there is a problem with the door stopper.

Step 2

Check the alignment between door stopper
and hinge to find out root causes.

Step 3

Check to see whether screw is screwed
correctly into final position. If not, this would cause misalignment between door stopper and hinge.

Step 5

Check if the door stopper is deformed and
causing misalignment.

DIAGNOSIS 1


PROCEDURE 1


Step 1

Unscrew hinge cover.

Step 2

Remove the cover.

Step 3

Disconnect the terminals.

Step 4

Unscrew bolts and remove the top hinge.

Step 5

Remove upper door.

Step 6

Tilt cabinet.

Step 7

Unscrew the adjustable foot.


Step 8

Unscrew the adjustable foot.

Reverse procedures above to install the door, please pay attention to the key points below.

Tip 1

Make sure gasket is attached well.