8.5 RELIABILITY FAULTS:
DOOR STOPPER IS BROKEN
CHECK AND TEST 1
Push the door to an angle of 8° from cabinet,
if the door doesn’t close automatically, there is a problem with the door stopper.
Check the alignment between door stopper
and hinge to find out root causes.
Check to see whether screw is screwed
correctly into final position. If not, this would cause misalignment between door stopper and hinge.
DIAGNOSIS 1
PROCEDURE 1
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Unscrew bolts and remove the top hinge.
Remove upper door.
Tilt cabinet.