CHECK AND TEST 1
Step 1
Unscrew cover of
mainboard with a
Cross-head screwdriver.
Check if terminal in PCB
area is inserted to final
position.
If not, reinsert it to final
position.
In PCB area, measure the resistance of defrost temp. sensor with a multimeter.
Take note of value.
Measure temperature of freezer temp. sensor. Use the measured temperature to find the standard resistance value in Temperature-Resistance Chart for Sensor.
DIAGNOSIS 1
PROCEDURE 1
Step 1
Remove all shelves.
Remove bottom drawer.
Remove drawer cover.
Step 6
Prize off the decorative
panel and take if off.
Step 8
Pull outward and take off
the upper air duct.
Step 9
Unscrew the lower
airduct.
Disconnect the connectors between airduct and cabinet.
Remove the lower air duct.
CHECK AND TEST 2
Step 1
Check if the terminal is
stuffed with foam.
Step 2
Measure resistance of
freezer temp. sensor from
terminal in freezer air duct
cover.
Step 5
Measure temperature
of freezer temp. sensor.
Use the measured
temperature to find the
standard resistance
value in TemperatureResistance Chart for
Sensor.
DIAGNOSIS 2
Disconnect the terminalCHECK AND TEST 3
DIAGNOSIS 3
When reinstalling the air duct, fasten the wires to avoid crushing with air duct.
CHECK AND TEST 4
Disassemble the LEDDIAGNOSIS 5
PROCEDURES 3
Tips for installing display.
After putting display into cavity, press edge until you hear a clicking sound, this means the board is pushed into final position
Please press all buttons on display board to make sure it works well.
PROCEDURE 6
Unscrew cover of mainboard with a Cross-head screwdriver
Prize off the connector buckles.
Disconnect the connectors.
Unscrew the mainboard.
Prize off the buckle to remove mainboard.
Reverse steps above to install a new mainboard.
DIAGNOSIS 6