PROCEDURE 1
Unscrew the screw of fridge air duct.
Remove the LED lamp cover and the screw.
Remove the air duct.
Unplug the electrical wires.
Disconnect the terminal of potentiometer.
Remove PCB box from air duct.
a) Use 2 mm slot screw driver to create a gap in front side.
b) Insert a steell ruler to even the gap.
c) Pull the PCB box out.
Disassemble PCB box.
a)Prize off the buckle;
b) Remove the cover;
c) Disconnect the terminals;
d) Unscrew and remove the PCB.
CHECK AND TEST 1
Reconnect the main control board to the cable.
Reconnect the electrical wires.
Press LED switch and hold on, then press the
button on mainboard for 3 seconds to start
manual defrost.
Please keep all terminals connected with
mainboard, otherwise, mainboard cannot
output power to heater.
Test voltage of terminals for defrost heater.
Take note of the result.
Later power off to quit manual defrost.
The value should be 230V or 115V.
DIAGNOSIS 1
PROCEDURE 1
CHECK AND TEST 2
Reconnect the main control board to the cable.
Reconnect the electrical wires.
Heat fridge temp. sensor.
Press LED switch and hold on, then press the
button on mainboard for 3 seconds to start
manual defrost.
Please keep all terminals connected with
mainboard, otherwise, mainboard cannot output power to heater.
Test voltage of terminals for defrost heater.
Take note of the result.
Later power off to quit manual defrost.
The value should be
230V or 115V.
DIAGNOSIS 2