PROCEDURE 1

Note

Capillary is covered by freezer air duct, you need to disassemble and remove freezer air duct to check.

Step 1

Remove freezer shelf.

Step 2

Lever 2 screw covers off.

Step 3

Unscrew 2 screws.

Step 4

Remove air duct:

a. Hold the air duct from air exit and pull air duct out;

c. Disconnect the terminal of fan motor;

d. Take air duct away.

CHECK AND TEST 1

Step 1

Check if:

1. Vibration-absorption soft rubber is missing;

2. Transitional pipe is aligned.

DIAGNOSIS 1

PROCEDURE 2

Tip 1

Firstly insert the air duct into the slot at the
bottom.

Tip 2

When reinstalling air duct, move wires out
of the way to prevent crushing with air duct.

Tip 3

After pushing air duct back into position, you
should hear a clicking sound. If there is no
click, please repeat again.