Capillary is covered by freezer air duct, you need to disassemble and remove freezer air duct to check.
PROCEDURE 1
Remove all glass
shelves.
Remove the upper air
duct.
a. Prize up and removeĀ the decorative cover.
Dismantle the air duct.
a. Unscrew the screws
(total four) with
Cross-head
screwdriver.
b. Catch the lower
air duct and pull down
the air duct.
c. Pay attention to the
connectors when
pulling out the air
duct.
d. Disconnect the
terminal for fan motor.
Disconnect the
terminal for defrost
sensor.
e. Move the air duct
out of the fridge
compartment.
Check if vibrationabsorption
mud isĀ missing;
Check if transitional pipe
is aligned.
Add more vibrationabsorption
soft rubber.
Please refer to red box.
Make sure the expansion
pipe is as straight as
possible.