8.5 RELIABILITY FAULTS:
DOOR STOPPER IS BROKEN

CHECK AND TEST 1
Push the door to an
angle of 8° from cabinet,
if the door doesn’t close
automatically, there is a
problem with the door
stopper.
Check the alignment
between door aid closer
and hinge to find out root
causes.
DIAGNOSIS 1
PROCEDURE 1
Tilt cabinet.
Unscrew the adjustable
foot.
Unscrew the hinge.

Remove bottom hinge.


CHECK AND TEST 2
Check to see whether
screw is screwed
correctly into final
position.
If not, rescrew it.
Check if the door aid
closer is deformed
and cracked, causing
misalignment.

DIAGNOSIS 2


PROCEDURE 2
Unscrew.
Remove aid-closer.
Reverse above steps to
install door aid-closer.

CHECK AND TEST 3
Check the metal piece is
deformed or not.


DIAGNOSIS 3