CHECK AND TEST 1
Unscrew cover of mainboard with cross-head screwdriver.
Power on the appliance, and heat freezer temp. sensor.
Use multimeter to test the voltage of output for fan.
Take note of the test result.
DIAGNOSIS 1
CHECK AND TEST 2
Open fridge door and heat fridge temp. sensor.
Press down fridge mechanical switch
Attach detecting hook to wires after stripping sleeves, use an oscilloscope to measure signal for damper between “A+” & “B+” or “A-” & “B-”
Power on the appliance and observe the signal for five seconds after opening or closing the door. Check to see if there is a square waveform output.
DIAGNOSIS 2
PROCEDURE 1
Disconnect terminals.
Unscrew the mainboard.
Pull out the buckle.
Remove the mainboard.
PROCEDURE 2
CHECK AND TEST 3
Power on the appliance, open fridge door, and press down fridge mechanical switch.
Put your hand near outlet
of fridge air duct to feel if there is cooling air
blowing out.
DIAGNOSIS 3