CHECK AND TEST 1
Discharge refrigerant.
a) Cut off the charging tube with a pair of pliers.
b) Discharge all refrigerant toward the exhaust vent.
Melt brazing material with flame and pull processing tube out using a pair of pliers.
To get more details on brazing requirements, please go to Annex B1
Install quick connector onto rebrazed pipe.
Cut off suction pipe and exhaust pipe.
Power on the compressor and test exhaust pressure coming from exhaust pipe with a piece of paper.
Use paper to test suction pressure from the suction pipe.
DIAGNOSIS 1
PROCEDURE 1
Open the metal clasp.
Disconnect all terminals.
Unscrew earthing wire.
Replace with new compressor.
Braze the joints of suction and exhasuting pipes.
Re-braze a copper tube onto processing tube of compressor.
To get more details on
brazing requirements,
please go to Annex B1
Note
Clean paint off of brazed joint of drying fiter.
Cut off the brazed point of drying fiter.
Cut off capillary and remove the cut end by shaking.
Braze on a new drying-filter.
Add quick connector onto processing pipe of drying-filter.
Conduct a leakage
test on brazed joints
of drying- lter and
compressor processing
pipe.
Vacuum and recharge.
Click below link to get more details for
vacuuming and gas-
charging requirements,
on Annex B2
Block processing pipe twice with locking pliers.
Leave locked pliers attached to second block and shake to cut off the remaining pipe.
Braze the ends and remove the pliers.
To get more details on brazing requirements, please go to Annex B1
Note
CHECK AND TEST 1
DIAGNOSIS 2