CHECK AND TEST 1
Unscrew cover of mainboard with a Cross-head screwdriver.
In mainboard area, check if terminal is inserted to final position.
If not, please reinsert into correct final position.
Set multimeter to resistance gear.
In PCB area, measure resistance of defrost
temp. sensor with a multimeter.
Step 6
Measure the temperature of freezer air duct, near the defrost temp. sensor.
Use measured temperature to find the standard resistance value in
Temperature-Resistance Chart of Sensor.
DIAGNOSIS 1
PROCEDURE 1
Remove all freezer drawers.
Remove all freezer shelves.
Remove screw covers (total of two) on upper
freezer air duct with Slotted Screw Driver.
Take out upper freezer air duct by tilting to one
side.
Pay attention to the connectors when pulling
out the air duct.
Disconnect the terminal for fan motor and move upper freezer air duct
away.
Remove the screw cover on bottom freezer air
duct with Slotted Screw Driver.
Unscrew the screw onbottom freezer air duct
with Cross-head screw driver.
CHECK AND TEST 2
DIAGNOSIS 2
CHECK AND TEST 3
DIAGNOSIS 3