8.6 RELIABILITY FAULTS:
DOOR STOPPER IS BROKEN
CHECK AND TEST 1
Push the door to a position with angle of
8o from cabinet, if the door doesn’t close
automatically, there is a problem with the door
stopper.
Check the alignment between door stopper
and hinge to find out root causes.
Check if bottom hinge is deformed and cause
misalignment.
Check if door stopper is deformed and cause
misalignment.
DIAGNOSIS 1
PROCEDURE 1
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Unscrew 3 bolts and remove the top hinge.
Remove the door.
Tilt cabinet by 10 degrees.
PROCEDURE 2