9.3 APPERANCE FAULT:
DOOR IS DAMAGED
DIAGNOSIS 1
PROCEDURE 1
Step 1
Unscrew hinge cover.
Step 2
Remove the cover.
Step 3
Disconnect the terminals.
Step 4
Unscrew 3 bolts and remove the top hinge.
Step 5
Remove fridge door.
PROCEDURE 2
Tip 1
When installing door
onto hinge, please check
the alignment between
door-stopper and hinge.
Tip 2
Make sure gasket is
attached well.
Tip 3
Make sure gaps
between doors are even.