CHECK AND TEST 1
Take note of the distance
(A) between door and
mechanical switch pin when
door is closed.
Power on the appliance,
open the door.
Check if LED light is on
or not.
Step 3
Press mechanical switch pin down for the
same distance (A) for 5 seconds.
Check if LED light is off
or not.
DIAGNOSIS 1
CHECK AND TEST 2
DIAGNOSIS 2
PROCEDURE 1
Remove the cover.
Step 3
Disconnect the terminal
in top hinge cover area.
Press the clip of the switch to loosen the
switch.
PROCEDURE 2
CHECK AND TEST 3
Improper Condition
Hinge cover is warped and misaligned with hinge.
Correct Condition
Hinge cover is well
aligned with hinge.
DIAGNOSIS 3
CHECK AND TEST 4
DIAGNOSIS 4
PROCEDURE 3
Reverse above
procedures in step 1
and 2 to install new
mechanical switch and
reinstall hinge cover.
CHECK AND TEST 5
DIAGNOSIS 5