CHECK AND TEST 1
Check thermostat gear. If gear is set close to Max (such as to 6 or 7) and compressor is always running, turn knob slowly to warmer gear until the compressor stops.
DIAGNOSIS 1
DIAGNOSIS 2
CHECK AND TEST 2
Set thermostat control knob to gear Min, and switch on the appliance.
Perform following 2 tests:
1 When compressor stops for second time, measure temp in the area near the thermostat bulb.
2 When the compressor starts again, measure temp. in the area near the thermostat bulb.
DIAGNOSIS 3
PROCEDURE 1
Lever off the screw cover.
Unscrew.
Remove thermostat cover.
Pull capillary from the hole.
Lever off the knob.
Disconnect terminal for thermostat.
PROCEDURE 2
When inserting capillary into the hole, make sure the first red mark goes in the hole, but second one remains outside of the hole.
CHECK AND TEST 3
DIAGNOSIS 4
DIAGNOSIS 5