CHECK AND TEST 1

Step 1

Check thermostat gear. If gear is set close to Max (such as to 6 or 7) and compressor is always running, turn knob slowly to warmer gear until the compressor stops. 

DIAGNOSIS 1





DIAGNOSIS 2

CHECK AND TEST 2

Step 1

Set thermostat control knob to gear Min, and switch on the appliance.

Step 2

Perform following 2 tests: 

1 When compressor stops for second time, measure temp in the area near the thermostat bulb. 

2 When the compressor starts again, measure temp. in the area near the thermostat bulb.

DIAGNOSIS 3

PROCEDURE 1 

Step 1

Lever off the screw cover.

Step 2

Unscrew.

Step 3

Remove thermostat cover.

Step 4

Pull capillary from the hole.

Step 5

Lever off the knob.

Step 6

Disconnect terminal for thermostat.

PROCEDURE 2

Tip 1:

When inserting capillary into the hole, make sure the first red mark goes in the hole, but second one remains outside of the hole.

Tip 2:

Make sure pins of thermostat cover are properly inserted into the holes.

Tip 3:

Make sure wires are pushed into cavity for thermostat.

CHECK AND TEST 3

Step 1

Set the knob of thermostat at gear MIN, and plug in to switch on the appliance.

Step 2

After first stop, please consult table 1 to find out bulb position, then measure temperature in the area of thermostat’s bulb.

DIAGNOSIS 4

DIAGNOSIS 5