CHECK AND TEST 1
Open the door to let internal temperature warm up to ambient temperature, then set gear to the coldest setting and let appliance run for 40 min.
Turn knob slowly to lowest gear until the compressor stops.
DIAGNOSIS 1
PROCEDURE 1
Lever off screw cover.
Remove screw cover
Remove thermostat cover.
Lever off the knob.
Disconnect terminal for thermostat.
DIAGNOSIS 2
PROCEDURE 2
Pull capillary from the hole to replace the thermostat.
When inserting capillary into the hole, make sure the first red mark goes in the hole, but second one remains outside of the hole.
Make sure the pins of thermostat cover are properly inserted into the holes.
Make sure wires are placed into cavity of thermostat.
DIAGNOSIS 3