CHECK AND TEST 1
Unscrew cover of mainboard with a Cross-head screwdriver.
In PCB area, check if
terminal is inserted to
final position.
If not, reinsert it to final
position.
Measure resistance of
heater from terminal in
PCB area.
Check the result.
Remove all shelves.
Remove basket.
Remove screw covers.
Unscrew.
Pull the buttom air duct
out.
Disconnect the wires for
thermostat.
Take bottom air duct
away.
Check if the terminal
is inserted into final
position.
Check if wires of defrost
heater are broken.
If yes, follow procedures
on Page 50 to replace
the heater.
Check to see if terminal is full of foam.
Check if the terminal is
stuffed with foam.
DIAGNOSIS 2
PROCEDURE 2
Disconnect terminal of
heater.
Unscrew the two screws
with 6mm cross-head
screwdriver.
Cut off the fastening
strap.
Take out the holding
foam.
Loosen heater fastening
clips.
Lift evaporator with
heater up 20mm. Bottom
of evaporator must be
higher than the edge of
water trough.
Do not damage the
wires of the heater while
installing the new heater.
CHECK AND TEST 3
Set multimeter to
resistance gear.
Put detector into one
end of wires in PCB area.
Put another detector into
end of wires behind air
duct.
CHECK AND TEST 4
Power on the appliance,
and press the button on
PCB to start manual defrost.
Put your hand close to
defrost heater.
Make sure the sealing
sponges are in good
condition.
When reinstalling the air
duct, fasten the wires to
avoid crushing with air
duct.
Check to see if there is
a wide gap between air
duct and cabinet. If there
is, reinstall air duct.